F23 Pelvic Model Review: Two Fetal Heads, One Pelvis

The BIX-F23 is a teaching pelvis with two fetal heads — one full-term, one premature — mounted on a flexible shaft so the head can be moved through the birth canal. The product page lists seven functions, from palpable sutures to forceps and vacuum demonstration.

Quick answer. Buy the F23 if you teach the mechanism of labour and need students to see and feel engagement, descent, flexion, rotation and extension on a physical pelvis. Do not buy it if you need a delivery simulator with a full body, a birth canal with soft tissue or a placenta.

At a glance

ItemDetail on the product pageTeaching consequence
ModelBIX-F23 pelvic model with fetal headPelvis plus fetal heads, no maternal body
ContentsFemale pelvis and two fetal headsTerm and preterm comparison in one set
Fetal skullSutures, anterior and posterior fontanelles palpablePalpation can be assessed, not just described
MountingHeads fixed on a flexible shaft through the pelvisPosition can be changed without detaching
MovementDemonstrates the seven cardinal movementsThe mechanism of labour becomes visible
Assisted deliveryForceps and vacuum can be demonstratedInstrument placement can be shown
Reference priceNot published on this pageQuotation required

What the two heads add

Most pelvic models ship with one fetal head, which forces the tutor to describe the difference between a term and a preterm skull. The F23 ships with two: one full-term, one premature. That single detail turns a demonstration into a comparison.

A preterm skull has different proportions and different suture spacing, and the fontanelles feel different under a finger. A student who has palpated both remembers the difference. In an assessment, the tutor can hand over one head without saying which it is and ask the student to justify a judgement — a task that is impossible with a single-head model.

The seven movements, made visible

The page lists the sequence explicitly: engagement, descent, flexion, internal rotation, extension, restitution, external rotation and delivery. That is the classic mechanism of labour taught in midwifery and obstetrics, and it is exactly the content that a textbook diagram flattens.

On the F23, the head is fixed on a flexible shaft, so the tutor can hold the pelvis and move the head through each step while the student narrates. The learning gain is not that the student sees a video; it is that the student's hand feels the resistance that produces flexion and the rotation that follows.

The clinical literature uses the same sequence. A standard reference chapter on normal labour defines the cardinal movements in this order and links engagement to the descent of the biparietal diameter below the pelvic inlet [1]. Intrapartum ultrasound studies have refined how engagement and rotation are assessed in practice, including the fetal head–symphysis distance and rotational descent, which gives the tutor a modern reference point for what the model is approximating [2][3].

A 30-minute demonstration that works

  1. Minutes 0–5 — landmarks. Student identifies the pelvic inlet, mid-plane and outlet, and names the diameters.
  2. Minutes 5–10 — engagement. Tutor places the term head at the inlet; student states what engagement means and why it is not the same as delivery.
  3. Minutes 10–18 — cardinal movements. Tutor moves the head; student narrates each movement before it happens, not after.
  4. Minutes 18–24 — preterm comparison. Swap to the preterm head; student describes two differences in palpation.
  5. Minutes 24–30 — assisted delivery. Demonstrate forceps and vacuum placement; student states the prerequisites and the risks.

The narration-before-movement rule is the assessment trick: it converts a passive demo into a prediction task.

What the F23 cannot teach

  • No soft tissue. The birth canal is bony; perineal stretching and laceration are not represented.
  • No station in centimetres. The model shows position, not a measured station.
  • No asynclitism or malposition beyond the shaft's range. Persistent occipitoposterior and brow presentations are not modelled.
  • No placenta or cord. Third-stage mechanisms are out of scope.
  • No maternal vital signs or pushing effort. The model is a mechanism trainer, not a delivery simulator.

Who should buy it

Buy the F23 for midwifery schools, obstetric nursing modules and simulation centres that teach the mechanism of labour before students enter a delivery room. It is also useful for informed-consent training, because a clinician can show a patient why a vacuum delivery is being considered.

Do not buy it as the only obstetric model in a programme that also teaches delivery, episiotomy or neonatal resuscitation; those need separate trainers.

Ask cprmodel@adaanatomy.com to confirm that the two fetal heads differ in size and that a spare flexible shaft can be quoted with the first order.

Procurement checklist

  1. Confirm both fetal heads are included and that the premature head is a different size, not a duplicate.
  2. Ask whether the flexible shaft can be replaced and at what price.
  3. Confirm the pelvis material and cleaning agent.
  4. Ask whether a stand or case is included.
  5. Request the packed dimensions and weight.
  6. Request ISO 9001, ISO 14001, ISO 45001 and CE certificates as PDFs.

Specifications and ordering facts

FieldValue
Product numberBIX-F23
CategoryPaediatrics and gynaecology models
SubjectPelvic model with fetal head
ContentsFemale pelvis, one full-term head, one premature head
PalpationCranial sutures, anterior and posterior fontanelles
DemonstrationSeven cardinal movements, forceps, vacuum
Reference priceNot published; quotation required
CertificationISO 9001, ISO 14001, ISO 45001, CE

FAQ

Q1. Are two fetal heads included? Yes. The page states one full-term and one premature head.

Q2. Can the fetal head be detached? The heads are fixed on a flexible shaft through the pelvis; they move but are not designed to be swapped on and off during a demonstration.

Q3. Does it show all seven cardinal movements? Yes. Engagement, descent, flexion, internal rotation, extension, restitution, external rotation and delivery are listed.

Q4. Can forceps and vacuum be demonstrated? Yes. The page lists both assisted delivery methods.

Q5. Is it a full delivery simulator? No. It is a pelvis and fetal head set for teaching mechanism, not a maternal body with soft tissue.

Q6. What is the price? No price is published on this page. Request a quotation with a spare flexible shaft.

References

  1. Normal Labor: Physiology, Evaluation, and Management. NCBI Bookshelf. https://www.ncbi.nlm.nih.gov/books/NBK544290/
  2. Youssef A, Dodaro M, Del Prete B, et al. 2021. The Fetal Head-Symphysis Distance in Intrapartum Ultrasound Assessment of the Fetal Head Engagement. Intrapartum Ultrasonography for Labor Management. https://doi.org/10.1007/978-3-030-57595-3_26
  3. Ghi T, Angeli L, Frusca T, et al. 2021. Fetal Head Rotation in Labor: Intrapartum Assessment at 2D and 3D Ultrasound. Intrapartum Ultrasonography for Labor Management. https://doi.org/10.1007/978-3-030-57595-3_23

Contact. For a quotation with a spare flexible shaft or a class set, email cprmodel@adaanatomy.com. Product page: https://www.cprmodel.com/pediatric-gynecological/pelvic-model-with-fetal-head-F23 · Paediatrics and gynaecology models: https://www.cprmodel.com/pediatric-gynecological-models · All articles: https://www.cprmodel.com/neslist.html

  • Phone:+86 13383897707  Tel:+86-0379-65160607  Email:cprmodel@adaanatomy.com
  • Marketing Center: Hong Kong, China    Production Base:Shanghai, China